Enum TriggerSource
- Namespace
- Harp.CameraControllerGen2
- Assembly
- Harp.CameraControllerGen2.dll
Specifies the source for generating the trigger signal.
public enum TriggerSource : byte
Fields
Internal = 0
Trigger is controlled by the device TriggerXCamX registers.
InternalReserved0 = 1
Reserved, do not use.
Internal1Hz = 2
Trigger is synchronously generated at 1Hz.
Internal2Hz = 3
Trigger is synchronously generated at 2Hz.
Internal5Hz = 4
Trigger is synchronously generated at 5Hz.
Internal10Hz = 5
Trigger is synchronously generated at 100Hz.
InternalReserved1 = 6
Reserved, do not use.
Internal20Hz = 7
Trigger is synchronously generated at 20Hz.
InternalReserved2 = 8
Reserved, do not use.
Internal40Hz = 9
Trigger is synchronously generated at 40Hz.
Internal50Hz = 10
Trigger is synchronously generated at 50Hz.
InternalReserved3 = 11
Reserved, do not use.
InternalReserved4 = 12
Reserved, do not use.
Internal100Hz = 13
Trigger is synchronously generated at 100Hz.
Internal125Hz = 14
Trigger is synchronously generated at 125Hz.
Input0 = 15
Trigger is controlled by the external input 0.