Manage battery charging

The Timestamp Generator Gen3 manages its internal battery automatically when connected to external power. You can configure the battery parameters for automatic charging, and also manually control charging in Bonsai.

This article covers how to adjust the charging thresholds, charge or discharge the battery manually, and run a battery cycle in Bonsai.

The complete workflow is shown below. Copy and paste it into Bonsai to get started immediately, or build each section by following the step-by-step instructions in the following sections.

Manage battery charging

Note

To verify that these commands are working correctly, you can monitor the battery voltage.

Warning

Battery charging requires external power and the BATTERY switch turned on. When the device is running from its battery, or when no battery is detected, the firmware cancels any active charge or discharge command and resumes normal function.

Set charging thresholds

Configure BatteryThresholdLow and BatteryThresholdHigh to set the voltages (in volts) at which automatic charging starts and stops. The defaults are 3.7 V and 3.8 V respectively.

Set charging thresholds

  • Insert a KeyDown operator and set the Filter property to A.
  • Insert a CreateMessage operator and configure the following properties:
    • Payload - Select BatteryThresholdLowPayload.
    • BatteryThresholdLow - Enter the voltage below which charging starts (e.g. 3.65).
  • Insert a MulticastSubject operator named TimestampGeneratorGen3 Commands.
  • Insert a second CreateMessage operator and configure the following properties:
    • Payload - Select BatteryThresholdHighPayload.
    • BatteryThresholdHigh - Enter the voltage above which charging stops (e.g. 3.85).
  • Insert a second MulticastSubject operator named TimestampGeneratorGen3 Commands.

Run the workflow and press A to write both thresholds. You can confirm the values by checking the battery charge or battery rate events.

Note

The firmware enforces hard safety limits regardless of the configured thresholds: charging always starts below 3.6 V and always stops above 4.1 V. Keep the automatic charging thresholds near the middle of this range to extend battery life.

Charge or discharge the battery

To temporarily override the automatic charging thresholds and control charging manually, you can set the battery mode using Config. This can be useful, for instance, if you need to fully charge the battery ahead of a planned power outage.

Charge or discharge the battery

  • Insert a KeyDown operator and set the Filter property to S.
  • Insert a CreateMessage operator and configure the following properties:
    • Payload - Select ConfigPayload.
    • Config - Select StartCharge to start battery charging.
  • Insert a MulticastSubject operator named TimestampGeneratorGen3 Commands.

In a separate branch:

  • Insert a KeyDown operator and set the Filter property to D.
  • Insert a CreateMessage operator and configure the following properties:
    • Payload - Select ConfigPayload.
    • Config - Select StartDischarge to start discharging.
  • Insert a MulticastSubject operator named TimestampGeneratorGen3 Commands.

Run the workflow and press S or D to charge or discharge the battery.

Note

A manual charge or discharge runs until it reaches the battery safety limits, and then returns to automatic control.

Run battery cycle

Running a battery cycle occasionally helps to extend the battery life. The battery cycle discharges the battery to the lower safety limit (3.6 V), charges it to the upper safety limit (4.1 V), and then discharges it back down to the high charging threshold (3.8 V by default) before resuming automatic control. The battery cycle is also controlled by sending Config commands.

Run battery cycle

  • Insert a KeyDown operator and set the Filter property to F.
  • Insert a CreateMessage operator and configure the following properties:
    • Payload - Select ConfigPayload.
    • Config - Select StartBatteryCycle.
  • Insert a MulticastSubject operator named TimestampGeneratorGen3 Commands.

In a separate branch:

  • Insert a KeyDown operator and set the Filter property to G.
  • Insert a CreateMessage operator and configure the following properties:
    • Payload - Select ConfigPayload.
    • Config - Select Stop to cancel the cycle.
  • Insert a MulticastSubject operator named TimestampGeneratorGen3 Commands.

Run the workflow and press F to start the cycle. Press G to cancel the cycle at any time and resume automatic control. The Stop command also stops the manual charge and discharge commands from the previous section.

Tip

A battery cycle can also be started from the device itself by holding the OPTION button.