Common Registers and Operation (Device 1.2)

Introduction

This document defines the common set of standard functionality that new Harp Device hardware should aim to provide. The goal is to create a common ground for the development and operation of Harp devices, and to allow quick and easy integration of new devices into the existing ecosystem. While some registers and functionalities are not mandatory, it is strongly recommended that they are implemented or, at least, considered with compatibility in mind.

Registers

Common Registers

The Common Registers are a set of registers that are common to all Harp Devices. These registers are used to identify the device, its version, and its operation mode. The Common Registers are mandatory and should be implemented in all Harp Devices. Summary description of each register can be found in [this table](ref missing).

All other registers pertaining to the operation of a specific device (Application Registers) should always take a register number equal, or greater, than 32. Moreoever, numbering and naming of these registers will be left to the developer, as they are specific to each device.

Operation Modes

A Harp Device is expected to implement the following Operation Modes:

  • Standby Mode: Replies to host commands. Events are disabled and must not be sent.
  • Active Mode: Replies to host commands. Events are enabled and sent to host whenever the device deems it so.
  • Speed Mode: Allows the implementation of a different and specific communication protocol. On this mode, the Harp Binary Protocol is no longer used. The specific protocol designed must implement the possibility to exit this mode.

The mandatory Operation Modes are the Standby Mode and Active Mode. The Speed Mode is optional and, in many of the applications, not needed. It’s strongly recommended that a Harp Device acting as peripheral should continuously check if the communication with the host is active and healthy. If this doesn’t happen over the last 3 seconds, the Harp Device should go to Standby Mode and flush/destroy its TX buffer.

Table - List of available Common Registers

Name Volatile Read Only Type Add. Default Brief Description Mandatory
R_WHO_AM_I - Yes U16 000 a) Who am I Yes
R_HW_VERSION_H - Yes U8 001 a) Major Hardware version Yes
R_HW_VERSION_L - Yes U8 002 a) Minor Hardware version Yes
R_ASSEMBLY_VERSION - Yes U8 003 a) Version of the assembled components Optional
R_CORE_VERSION_H - Yes U8 004 a) Major core version Optional
R_CORE_VERSION_L - Yes U8 005 a) Minor core version Optional
R_FW_VERSION_H - Yes U8 006 a) Major Firmware version of the application Yes
R_FW_VERSION_L - Yes U8 007 a) Minor Firmware version of the application Yes
R_TIMESTAMP_SECOND Yes No U32 008 0 System timestamp: seconds Yes
R_TIMESTAMP_MICRO Yes Yes U16 009 0 System timestamp: microseconds Optional
R_OPERATION_CTRL No No U8 010 b) Configuration of the operation mode c)
R_RESET_DEV No No U8 011 b) Reset device and save non-volatile registers Optional
R_DEVICE_NAME No No U8 012 b) Name of the device given by the user Optional
R_SERIAL_NUMBER No No U16 013 b) Unique serial number of the device Optional
R_CLOCK_CONFIG No No U8 014 b) Synchronization clock configuration Optional
R_TIMESTAMP_OFFSET No No U8 015 b) Adds an offset if user updates the Timestamp Optional
a) These values are stored during factory process and are persistent, i.e., they cannot be changed by the user.
b) Check register notes on the specific register explanation
c) Only parts of the functionality is mandatory. Check register notes on the explanation.

R_WHO_AM_I (U16) – Who Am I

Address: 000

Used to verify the identity of the device. A list of devices can be found at https://github.com/harp-tech/protocol. To reserve a range or certain IDs for your project or company, please follow the instructions in this repository. If the device doesn’t have a pre-allocated ID on the IDs list, this register should be set as 0.

---
displayMode: compact
---

gantt
    title R_WHO_AM_I (000) [U16]

    dateFormat X
    axisFormat %
    tickInterval 0

    section Bit
    15-8      :byte1, 0, 1
    7-0      :byte0, after byte1  , 2
    section Id
    WHO_AM_I      :id1, 0, 2
    section Default
    0      :d1, 0, 2

R_TIMESTAMP_SECOND (U32) – System timestamp (seconds)

Address: 008

Contains the current system timestamp in whole seconds. The default value is 0 (ZERO) and will increment one unit for each elapsed second.


---
displayMode: compact
---

gantt
    title R_TIMESTAMP_SECONDS (008) [U32]

    dateFormat X
    axisFormat %
    tickInterval 0

    section Bit
    31-24      :byte3, 0, 1
    23-16      :byte2, after byte3  , 2
    15-8      :byte1, after byte2  , 3
    7-0      :byte0, after byte1  , 4
    section Id
    SECONDS      :id1, 0, 4
    section Default
    0      :d1, 0, 4

R_TIMESTAMP_MICRO (U16) – System timestamp (microseconds)

Address: 009

Contains the microseconds count within each second. Each LSB corresponds to 32 microseconds. The maximum value is 31249.

---
displayMode: compact
---

gantt
    title R_TIMESTAMP_SECONDS (009) [U16]

    dateFormat X
    axisFormat %
    tickInterval 0

    section Bit
    15-8      :byte1, 0, 1
    7-0      :byte0, after byte1  , 2
    section Id
    USECONDS      :id1, 0, 2
    section Default
    -      :d1, 0, 2

R_OPERATION_CTRL (U16) – Operation mode configuration

Address: 010


---
displayMode: compact
---

gantt
    title R_OPERATION_CTRL (010)
    dateFormat X
    axisFormat %

    section Bit
    7      :bit7, 0, 1
    6      :bit6, after bit7  , 2
    5      :bit5, after bit6  , 3
    4      :bit4, after bit5  , 4
    3      :bit3, after bit4  , 5
    2      :bit2, after bit3  , 6
    1      :bit1, after bit2  , 7
    0      :bit0, after bit1  , 8
    section Id
    ALIVE_EN      :id7, 0, 1
    OPLEDEN      :id6, after bit7  , 2
    VISUALEN      :id5, after bit6  , 3
    MUTE_RPL      :id4, after bit5  , 4
    DUMP      :id3, after bit4  , 5
    -      :id2, after bit3  , 6
    OP_MODE      :id1, after id2  , 8
    section Default
    1      :d7, 0, 1
    1      :d6, after bit7  , 2
    1      :d5, after bit6  , 3
    0      :d4, after bit5  , 4
    0      :d3, after bit4  , 5
    -      :d2, after bit3  , 6
    0      :d1, after d2  , 8
    section Implementation
    Optional      :i7, 0, 1
    Optional      :i6, after bit7  , 2
    Optional      :i5, after bit6  , 3
    Optional      :i4, after bit5  , 4
    Optional      :i3, after bit4  , 5
    -      :i2, after bit3  , 6
    a)      :i1, after i2  , 8


a) Standby Mode and Active Mode are mandatory. Speed Mode is optional.

  • OP_MODE [Bits 1:0]: These bits define the operation mode of the device. Note that, if Speed Mode is selected, the device will no longer reply to the HARP commands, only to its specific Speed Mode commands.

Table - Available Operation modes

OP_MODE[1:0] Configuration
0 Standby Mode. The device has all the Events turned off.
1 Active Mode. The device turns ON the Events detection. Only the enabled Events will be operating.
2 Reserved.
3 Speed Mode. The device enters Speed Mode.
  • DUMP [Bit 3]: When written to 1, the device adds the content of all registers to the streaming buffer as Read messages. This bit is always read as 0.
  • MUTE_RPL [Bit 4]: If set to 1, the Replies to all the Commands are muted, i.e., they will not be sent by the device.
  • VISUALEN [Bit 5]: If set to 1, visual indications, typically LEDs, available on the device will operate. If equals to 0, all the visual indications should turn off.
  • OPLEDEN [Bit 6]: If set to 1, the LED present on the device will indicate the Operation Mode selected.

Table - Visual LED toggle feedback

Period (s) Operation Mode
4 Standby Mode.
2 Active Mode.
1 Speed Mode.
0.1 A critical error occurred. Only a hardware reset or a new power up can remove the device from this Mode.
  • ALIVE_EN [Bit 7]: If set to 1, the device sends an Event Message with the R_TIMESTAMP_SECONDS content each second (i.e. Heartbeat). This allows the host to check that the device is alive. Although this is an optional feature, it’s strongly recommended to be implemented.

R_RESET_DEV (U8) – Reset device and save non-volatile registers

Address: 011

---
displayMode: compact
---
gantt
    title R_RESET_DEV (011)
    dateFormat X
    axisFormat %

    section Bit
    7      :bit7, 0, 1
    6      :bit6, after bit7  , 2
    5      :bit5, after bit6  , 3
    4      :bit4, after bit5  , 4
    3      :bit3, after bit4  , 5
    2      :bit2, after bit3  , 6
    1      :bit1, after bit2  , 7
    0      :bit0, after bit1  , 8
    section Id
    BOOT_EE      :id7, 0, 1
    BOOT_DEF      :id6, after bit7  , 2
    -      :id5, after bit6  , 3
    -      :id4, after bit5  , 4
    NAME_TO_DEFAULT      :id3, after bit4  , 5
    SAVE      :id2, after bit3  , 6
    RST_EE      :id1, after id2  , 7
    RST_DEF      :id0, after id1  , 8

    section Default
    -      :d7, 0, 1
    -      :d6, after bit7  , 2
    -      :d5, after bit6  , 3
    -      :d4, after bit5  , 4
    0      :d3, after bit4  , 5
    0      :d2, after bit3  , 6
    0      :d1, after bit2  , 7
    0      :d0, after bit1  , 8
  • RST_DEF [Bit 0]: If set to 1, the device resets and, reboots with all the registers, both Common and Application, with the default values. EEPROM will be erased, and the default values will be restored as the permanent boot option. This bit is always read as 0.

  • RST_EE [Bit 1]: If set to 1, the device resets and reboots with all the registers, both Common and Applicatin registers, with the values saved on the non-volatile memory, usually an EEPROM. The EEPROM values will remain the permanent boot option. This bit is always read as 0.

  • SAVE [Bit 3]: If set to 1, the device will save all the non-volatile registers (both Common and Application) to the internal non-volatile memory, and reboot. The non-volatile memory should be the permanent boot option.

  • NAME_TO_DEFAULT [Bit 4]: If set to 1, the device will reboot with the default name. This bit is always read as 0.

  • BOOT_DEF [Bit 6]: A read-only state bit that indicates whether the device booted with the default register values or not.

  • BOOT_EE [Bit 7]: A read-only state bit that indicates whether the device booted with the register values saved on the EEPROM or not.

Note

To avoid unexpected behaviors, only one bit at a time should be written to register R_RESET_DEV.

R_DEVICE_NAME (25 Bytes) – Device's name

Address: 012

An array of 25 bytes that should contain the device name. The last, and unused, bytes must be equal to 0. This register is non-volatile. The device will reset if this register is written to.

R_SERIAL_NUMBER (U16) – Device's serial number

Address: 013

---
displayMode: compact
---

gantt
    title R_SERIAL_NUMBER (013) [U16]

    dateFormat X
    axisFormat %
    tickInterval 0

    section Bit
    15-8      :byte1, 0, 1
    7-0      :byte0, after byte1  , 2
    section Id
    SERIAL_NUMBER      :id1, 0, 2
    section Default
    -      :d1, 0, 2

This number should be unique for each unit of the same Device ID. To write to this register a two-step write command is needed. First, write the value 0xFFFF, and then the desired serial number (as a U16). The device will reset after the second write command is received.

R_CLOCK_CONFIG (U8) – Synchronization clock configuration

Address: 014

---
displayMode: compact
---
gantt
    title R_CLOCK_CONFIG (014)
    dateFormat X
    axisFormat %

    section Bit
    7      :bit7, 0, 1
    6      :bit6, after bit7  , 2
    5      :bit5, after bit6  , 3
    4      :bit4, after bit5  , 4
    3      :bit3, after bit4  , 5
    2      :bit2, after bit3  , 6
    1      :bit1, after bit2  , 7
    0      :bit0, after bit1  , 8
    section Id
    CLK_LOCK      :id7, 0, 1
    CLK_UNLOCK      :id6, after bit7  , 2
    -      :id5, after bit6  , 3
    GEN_ABLE      :id4, after bit5  , 4
    REP_ABLE      :id3, after bit4  , 5
    -      :id2, after bit3  , 6
    CLK_GEN      :id1, after id2  , 7
    CLK_REP      :id0, after id1  , 8

    section Default
    0      :d7, 0, 1
    1      :d6, after bit7  , 2
    -      :d5, after bit6  , 3
    -      :d4, after bit5  , 4
    -      :d3, after bit4  , 5
    -      :d2, after bit3  , 6
    -      :d1, after bit2  , 7
    -      :d0, after bit1  , 8
  • CLK_REP [Bit 0]: If set to 1, the device will repeat the Harp Synchronization Clock to the Clock Output connector, if available. It will act has a daisy-chain, by repeating the Clock Input to the Clock Output. Setting this bit, also unlocks the Harp Synchronization Clock.

  • CLK_GEN [Bit 1]: If set to 1, the device will generate Harp Synchronization Clock to the Clock Output connector, if available. The Clock Input will be ignored. The bit is read as 1 if the device is generating the Harp Synchronization Clock.

  • REP_ABLE [Bit 3]: This is a read-only bit signaling if the device is able (1) to repeat the Harp Synchronization Clock timestamp.

  • GEN_ABLE [Bit 4]: This is a read-only bit signaling if the device is able (1) to generate the Harp Synchronization Clock timestamp.

  • CLK_UNLOCK [Bit 6]: If set to 1, the device will unlock the timestamp register counter (register R_TIMESTAMP_SECOND) and it will now accept new timestamp values. The bit is read as 1 if the timestamp register is unlocked.

  • CLK_LOCK [Bit 7]: If set to 1, the device will lock the current timestamp register counter (register R_TIMESTAMP_SECOND) and it will reject any new timestamp values. The bit is read as 1 if the timestamp register is locked.

Note

The device always wakes up in the unlock state.

R_TIMESTAMP_OFFSET (U8) – Clock calibration offset

Address: 015

---
displayMode: compact
---

gantt
    title R_TIMESTAMP_OFFSET (000) [U8]

    dateFormat X
    axisFormat %
    tickInterval 0

    section Bit
    7-0      :byte1, 0, 1
    section Id
    UOFFSET      :id1, 0, 1
    section Default
    0      :d1, 0, 1

When the value of this register is above 0 (zero), the device’s timestamp will be offset by this amount. The register is sensitive to 500 microsecond increments. This register is non-volatile.

Release notes:

  • v0.2

    • First draft released.
  • v1.0

    • R_RESET_DEV and R_DEVICE_NAME are now optional.
    • Changed Normal Mode to Standby Mode.
    • Added bit ALIVE_EN to register R_OPERATION_CTRL. This is an important feature.
    • Major release.
  • v1.1

    • Added bit MUTE_RPL to register R_OPERATION_CTRL.
  • v1.2

    • Corrected some wrong names.
  • v1.3

    • Added the bit NAME_TO_DEFAULT.
  • v1.4

    • Added the register R_SERIAL_NUMBER.
  • v1.5

    • Added the register R_CLOCK_CONFIG.
  • v1.6

    • Changed device naming to Controller and Peripheral.
  • v1.7

    • Raised version to 1.2 since all the foreseen features are included at this point.
    • Added the register R_TIMESTAMP_OFFSET.
  • v1.8

    • Replaced HARP_VERSION with CORE_VERSION.
  • v1.9.0

    • Refactor documentation to markdown format.
    • Minor typo corrections.
    • Improve clarity of some sections.
    • Adopt semantic versioning.
  • v1.9.1

    • Remove table of contents to avoid redundancy with doc generators.
    • Minor improvements to clarity of introduction.